Jaz
The World's Coolest Modular Measuring Suite
Talk about innovation in optical sensing! Jaz is like nothing you’ve ever seen before -- a community of stackable, modular and autonomous components that combine to create a family of smart sensing instruments. Jaz is unfettered by the limits of traditional optical sensing instrumentation: a powerful microprocessor and onboard display eliminate the need for a PC; stackable, autonomous instrument modules allow you to customize the system to your changing application needs; and Ethernet connectivity plus an SD card for data storage make remote operation a snap!

[more details]

Jaz Modules & Specifications at a Glance

Jaz Spectrometer Module
Detector: Sony ILX511B linear CCD array (200-1100 nm)
Grating options: 14 gratings, UV through Shortwave NIR
Slits: select from 5, 10, 25, 50, 100 or 200 µm widths
Fiber optic connector: SMA 905
Wavelength Range: Maximum 650 nm
Optical Resolution: ~0.3 - 10.0 nm (FWHM)
Signal-to-noise ratio: 250:1
Dark noise: 50 RMS counts
Dynamic range: 1300:1
Integration time: 4 ms - 65 seconds
Power consumption: ~2.5 W
Jaz OLED Display Module
OLED display: 128 x 64 OLED display
Keypad: push-button functions easy to read from any orientation
Onboard computer: embedded processor with data processing and storage capability
Additional interfaces: USB 2.0; GPIO for triggering and other functions
Jaz Ethernet and Memory Module
Ethernet: 100 Mbps, IEEE 802.3-compliant 10/100
Data storage: via SD card
Jaz Battery and Memory Module
Type: rechargeable Lithium-Ion
Life: 8 hours before recharging
Jaz UV-VIS Light Source Module
Type: UV-VIS deuterium-tungsten halogen
Bulb life (estimated): 800 hours for deuterium; 1100 hours for tungsten
Jaz LS450 Light Source Module
Type: LS-450 LED
 

Maya 2000 and 2000 Pro
The Ocean Optics line of high-sensitivity back-thinned 2D FFT-CCD spectrometers for low light-level, UV-sensitive and other scientific applications now includes three versatile options: an improved version of our thermoelectrically cooled QE65000 Spectrometer, distinguished by improved stray light and low noise characteristics; and the uncooled Maya2000 and Maya2000 Pro, which offer greater than 90% quantum efficiency, high dynamic range and excellent UV response.

[more details]
 

Detector Specifications
  Maya 2000
Detector: Hamamatsu S9840
Architecture: Back-thinned, 2D
Thermoelectric cooling: No
# of Pixels: All: 2080 x 20
Active: 2048 x 14
Pixel size: 14 um square
Column height 196 um
Detector active area (mm): 28.672 horizontal x 0.196 vertical
Well depth: 130Ke-
Peak QE >90%
QE @ 250 nm 55%
CCD effective number of bits: ~12 bit
Spectrometer Specifications
  Maya 2000
Integration time: 5 ms - 20 seconds
A/D converter: 16 bit, 500 kHz
Dynamic range: 5000:1 (typical: ~8000:1)
Signal-to-noise ratio: 350:1
Non-linearity (uncorrected): ~4.0%
Linearity (corrected): <1.0%
Column sensitivity: ~0.45 Counts/e-
Detector Specifications
  Maya 2000 Pro
Detector: Hamamatsu S10420
Architecture: Back-thinned, 2D
Thermoelectric cooling: No
# of Pixels: All: 2068 x 70
Active: 2048 x 64
Pixel size: 14 um square
Column height: 896 um
Detector active area (mm): 28.672 horizontal x 0.896 vertical
Well depth: 200Ke-
Peak QE 75%
QE @ 250 nm 65%
Spectrometer Specifications
  Maya 2000 Pro
Integration time: 8 ms – 10 seconds
A/D converter: 16 bit, 250 kHz
Dynamic range: 10000:1 (typical: ~12000:1)
Signal-to-noise ratio: 450:1
Non-linearity (uncorrected): ~1%
Linearity (corrected): <0.03%
Column sensitivity: ~0.32 Counts/e-

Optical Transmittance Spectroscopy
The Ocean Optics Optical Transmittance Spectrophotometer (OTiS) is ideal for both in-line and in-lab applications where transmittance accuracy (to +/- 1.0%) and precision (+/- 0.1%) are critical. Common applications include measurement of optical coatings, windows and filters, and glass and plastic components.

[more details]

User-configured Spectrometers
 
User-configured spectrometers are for those who wish to select components and options in their spectrometer, from the wavelength range and grating type to the size of the entrance aperture and type of coatings on the detector. Need results today? Click here
-- in stock and ready to ship! --
 

Spectrometer Related Links Detector Range*
USB2000+ Miniature Fiber Optic Spectrometer + Optical Bench Options
+ Choosing a Grating & Wavelength Range
+ Grating Efficiency Charts
+ Predicted Range & Resolution Charts
200-1100 nm
USB4000 Miniature Fiber Optic Spectrometer + Optical Bench Options
+ Choosing a Grating & Wavelength Range
+ Grating Efficiency Charts
+ Predicted Range & Resolution Charts
200-1100 nm
HR4000 High-resolution Spectrometer

-- in stock and ready to ship! --
+ Optical Bench Options
+ Choosing a Grating & Wavelength Range
+ Grating Efficiency Charts
+ Predicted Range & Resolution Charts
200-1100 nm
HR2000+ High-resolution Spectrometer + Optical Bench Options
+ Choosing a Grating & Wavelength Range
+ Grating Efficiency Charts
+ Predicted Range & Resolution Charts
200-1100 nm
QE65000 Scientific-grade Spectrometer + Optical Bench Options
+ Choosing a Grating & Wavelength Range
+ Grating Efficiency Charts
+ Predicted Range & Resolution Charts
200-1100 nm
NIR-512 Near-infrared Spectrometer + Optical Bench Options
+ Choosing a Grating & Wavelength Range
+ Grating Efficiency Charts
900-1700 nm
NIR256-2.1 NIR Spectrometer
and
NIR256-2.5 Extended-range NIR Spectrometer
+ Optical Bench Options
+ Choosing a Grating & Wavelength Range
+ Grating Efficiency Charts
900-2100 nm
and
900-2550 nm

* This is the Detector Range only. Wavelength Range is determined by the grating selected.

Fluorescence Spectrometers

The following options are available for fluorescence measurements.
 

Spectrometer Systems and Setups

Systems and setups are either turnkey spectrometers or complete setups necessary for a specific measurement technique, such as fluorescence, or a specific application, such as measuring LEDs.
 

Spectrometer Purpose Wavelength Range
Brontes Colorimeter Color measurement system 380-780 nm
LAMPS Laser-Assisted Microwave Plasma Spectroscopy 200-980 nm
USB4000-UV-VIS Spectrometer

-- in stock and ready to ship! --
General-purpose 200-850 nm
USB4000-VIS-NIR Spectrometer

-- in stock and ready to ship! --
General-purpose 350-1000 nm
HR4000CG-UV-NIR Broadband Spectrometer General purpose, Broadband 200-1100 nm
HR2000+CG Spectrometer General purpose, Broadband 200-1100 nm
CHEM4-UV-VIS Spectrophotometer General-purpose, Education 210-880 nm
CHEM4-VIS-NIR Spectrophotometer General-purpose, Education 370-985 nm
CHEM4-UV-FIBER Spectrophotometer General-purpose, Education 200-885 nm
CHEM4-VIS-FIBER Spectrophotometer General-purpose, Education 430-990 nm
USB650 Red Tide General-purpose, Education 350-1000 nm
USB650-UV-VIS Red Tide General-purpose, Education 200-850 nm
USB650-VIS-NIR Red Tide General-purpose, Education 350-1000 nm
DTS-series MEMS-based NIR Spectrometers General Purpose, NIR 0.9-2.5 µm
DTS-PHAZIR-1016 and DTS-PHAZIR-1624 MEMS-based NIR Material Analyzers General Purpose, NIR 1000-1600 nm and
1600-2400 nm
Process-2000 Multi-channel Systems Process Control Multiple options
FIA-LAB-2500 Flow Injection Analysis System Liquid Absorbance System Multiple options
S1024DW Deep Well Spectrometer Liquid Absorbance System Multiple options
LIBS Broadband Spectrometer System Laser Induced Breakdown Spectroscopy 200-980 nm
QE65000 Scientific-grade Spectrometer Raman Spectroscopy 200-1100 nm
Raman Systems R-3000 Spectrometers Raman Spectroscopy ~200-2700 cm-1
RSL-Plus Handheld Raman System Raman Spectroscopy ~200-2400 cm-1
LED Measurement Tools Spectroradiometric Analysis Multiple options
Spectroradiometric Tools Spectroradiometric Analysis Multiple options
NanoCalc Thin Film Reflectometry System* Metrology Multiple options
SpecEl Ellipsometer System Metrology 450-900 nm
PlasCalc Plasma Monitoring System Metrology 200-1100 nm
Optical Transmittance System Metrology 380-850 nm
Hydrorad Environmental Radiometer* Radiometry Multiple options
SEA Spectrometer Series for Lighting Professionals General Purpose Multiple Options

 

 

 


PRODUCTS | TECHNICAL | APPLICATIONS | CORPORATE | DISTRIBUTORS | PRIVACY POLICY
CONTACT US
| CATALOG | PRICE LIST | ORDER INFO


.
©2007 Ocean Optics, Inc. All rights reserved.  Terms of Use and Privacy Statement
+1 727.733.2447 • +1 Fax 727.733.3962 •

 

 

- Jaz

- Maya

- OTS

- User-configured

- Fluorescence

- Systems

 

- Spectrometer Operating Principles

- Determining Spectrometer Optical Resolution

- Spectrometer System Sensitivity

- Detector Information

- Recalibration Whitepaper

- Need speed? Check out our USB4000/HR4000 conversion offer

ADC1000-USB A/D Converter